Cisco CCNA (200-301) free question 1 / 10 · Domain 1: Network Infrastructure and Connectivity
Users on a floor report very slow transfers and sessions that drop at random. On the access switch, the port that serves them is set to full duplex. Its show interfaces output shows the FCS, alignment and runt counters climbing quickly, and the collision counter stays at zero. What should the engineer check first?
- Whether the connected device is running at half duplex, which would be a duplex mismatch with the full-duplex switch port
- Whether heavy half-duplex traffic on a shared segment is generating the expected collisions along with the errors that come with them
- Whether the traffic load toward the switch port is high enough to cause deferred frames
- Whether the connected NIC is transmitting frames larger than the 1518-byte maximum
Show the answer and explanation
Answer: A
Why this is correct
The counter page separates half-duplex and full-duplex behavior. At half duplex, some FCS, alignment, runt and collision counts are normal because both ends can transmit at the same moment. At full duplex, those error counters should stay minimal and the collision counter is not active, so a rising FCS, alignment or runt count points to a duplex mismatch. A mismatch means one side runs full duplex and the other half duplex, and the page lists extremely slow performance, intermittent connectivity and loss of connection as the results.
Why the other options are wrong
"Whether heavy half-duplex traffic on a shared segment is generating the expected collisions along with the errors that come with them" … A full-duplex link does not use the collision counter, and the page says it is not active at full duplex. The collision counter here is zero, so a busy half-duplex segment does not explain the climbing error counters.
"Whether the connected NIC is transmitting frames larger than the 1518-byte maximum" … Frames above the maximum size are counted as giants, a different counter. Runts are frames smaller than 64 bytes, so oversized frames would not raise the runt counter.
"Whether the traffic load toward the switch port is high enough to cause deferred frames" … Deferred frames count transmissions that were delayed by traffic on the media and later sent without error. They are not corrupted frames, so they do not raise FCS, alignment or runt counters.
Key points
A zero collision counter with climbing FCS, CRC, alignment or runt counters on a full-duplex port is the pattern that points to a duplex mismatch. The page names bad cables, faulty switch ports and NIC software or hardware issues as other possible causes at full duplex.
Go to the Cisco CCNA (200-301) practice app (10 free questions; purchase unlocks all questions)