Cisco 300-420 ENSLD (Designing Cisco Enterprise Networks) free question 1 / 10 · Domain 1: Advanced Addressing and Routing Solutions
A reviewer states that the hello interval has to be the same on both ends of every IS-IS link. Which statement about the design is correct?
- Hello timers have to match, and so does the area ID at Level 1 and Level 2
- Hello timers have to match, and authentication may differ on the two ends
- Hello timers have to match at Level 2 and may differ at Level 1
- Hello timers need not match, but authentication and network type must
Show the answer and explanation
Answer: D
Why this is correct
The page states that hello timers need not match for the adjacency to come up. The settings that do have to agree include the network type and any configured authentication, and the page also gives circuit type and MTU as common causes of failed adjacencies. A design standard should therefore name those items, not the hello interval, as the mandatory matches.
Why the other options are wrong
"Hello timers have to match, and authentication may differ on the two ends" … It is the reverse. The page says hello timers need not match and that authentication, if configured, must match on both ends.
"Hello timers have to match at Level 2 and may differ at Level 1" … The page makes no distinction between levels for hello timers. They need not match for the adjacency to come up.
"Hello timers have to match, and so does the area ID at Level 1 and Level 2" … Timers need not match. Area ID matching is required only for Level 1 adjacencies, and a Level 2 adjacency does not depend on it.
Design takeaway
Do not make the hello interval a mandatory match in a design review. Network type, authentication and compatible circuit types are the real requirements.